Get the latest price? We will reply as soon as possible (within 12 hours)

Spectrum Analyzer Product Introduction

2025-07-25

Spectrum Analyzer Product Introduction


1. Product Overview
The Spectrum Analyzer is a precision electronic instrument designed to measure and display the frequency spectrum of input signals. It is widely used in RF engineering, telecommunications, and research to analyze signal characteristics such as amplitude, distortion, and noise across specified frequency ranges.



2. Key Functions

  • Frequency Analysis: Measures signal power distribution across 9 kHz to 44 GHz (model-dependent).

  • Modulation Analysis: Supports AM/FM/PM and digital modulation (QPSK, QAM).

  • Noise Detection: Identifies spurious signals with DANL (Displayed Average Noise Level) ≤-155 dBm.

  • Real-Time Processing: Captures transient signals with 100% POI (Probability of Intercept).


3. Working Principles

  • Superheterodyne Architecture: Downconverts RF signals to IF for precise measurement.

  • FFT-Based Digital Processing: Enables real-time spectrum updates (up to 200 spectra/sec).

  • Advanced Triggering: Supports power/edge/frame triggers for complex signal capture.


4. Usage Methods
Step 1: Setup

  • Connect the input via SMA/N-type connectors (50Ω impedance).

  • Set frequency span (e.g., 1 MHz–6 GHz) and RBW (1 Hz–3 MHz).


Step 2: Measurement

  • Use Peak Search to identify dominant frequencies.

  • Apply Markers for amplitude/frequency readouts.


Step 3: Data Export

  • Save traces in CSV/PNG format via USB/LAN.


5. Technical Specifications

ParameterSpecification
Frequency Range9 kHz–44 GHz
Amplitude Accuracy±0.5 dB
Phase Noise≤-110 dBc/Hz @ 10 kHz offset
InterfaceUSB 3.0, GPIB, Ethernet


6. Applications

  • 5G NR Testing: Analyzes EVM (Error Vector Magnitude) for base stations.

  • EMI Pre-Compliance: Detects radiated emissions per CISPR 32.

  • Radar Verification: Measures pulse width/PRF (Pulse Repetition Frequency).


7. Safety & Compliance

  • Certifications: CE, FCC Part 15, RoHS.

  • Operating Conditions: 0°C–50°C, ≤80% RH (non-condensing).